McQuay Duct Sizer Free Download (v6.4) – HVAC Duct Sizing Software

MEPbase StaffUpdated 6 min read

McQuay Duct Sizer is a free Windows tool that sizes HVAC ducts in seconds. Enter the airflow, set a friction rate or a velocity limit, and it gives the round duct diameter, the equivalent rectangular sizes and the pressure drop. On this page you can download McQuay Duct Sizer v6.4 (also written as DuctSizer), see how to use it with a worked example, and find an online option for when you cannot run software.

It is made for HVAC design engineers, MEP draftsmen and site engineers who need a fast duct size check during design, shop drawing preparation and site coordination.

McQuay Duct Sizer v6.4 free download - DesignTools DuctSizer software

File Information

  • Software Name: McQuay DesignTools DuctSizer
  • Version: 6.4
  • Developer: McQuay International (now Daikin Applied)
  • File Type: Portable .exe, no installation
  • File Size: Less than 1 MB
  • Works On: Windows XP to Windows 11, 32-bit and 64-bit
  • Language: English
  • Usage: Free

What McQuay Duct Sizer Does

  • Sizes round and rectangular ducts: get the round diameter first, then pick a rectangular size with the same performance.
  • Works from any two inputs: tick two of Flow rate, Head loss, Velocity and Equivalent diameter, and the tool calculates the rest.
  • Shows the full air data: flow area, fluid velocity, Reynolds number, friction factor, velocity pressure and head loss.
  • Controls velocity: size by a velocity limit to keep noise within the project requirement.
  • Opens instantly: one small file, no installation and no licence key.

How to Use McQuay Duct Sizer

  1. Open DuctSizer.exe. The fluid is set to 68°F Air STP. Change it from the drop-down list if your design condition is different.
  2. Tick the two values you know. Flow rate and Head loss are ticked when the tool opens.
  3. Type the airflow in the Flow rate box, in cfm.
  4. Type the friction rate in the Head loss box, in in.WC/100 ft. To size by velocity instead, tick Velocity and type the limit in fpm.
  5. Read the results. The tool lists Equivalent Diameter, Flow Area, Fluid velocity, Reynolds Number, Friction factor, Velocity Pressure and Head Loss.
  6. Get a rectangular size. Type the duct height in the first Duct size box, for example the depth your ceiling allows. The tool gives the width.

Use the Units menu to change units, Clear to start a new duct and Print to print the result.

Worked Example: 1,377 CFM Supply Duct

A supply duct carries 1,377 cfm (about 650 L/s). Type 1377 in Flow rate and 0.05 in Head loss, and the tool gives the velocity and the round duct size on its own. Then type a height of 12 in. in the Duct size box, and the tool gives a width of 23 in.

McQuay Duct Sizer example - 1377 cfm at 0.05 in.WC per 100 ft gives 18 in round or 12 x 23 in rectangular duct

Item Value Source
Flow rate 1,377 cfm (650 L/s) You type
Head loss 0.05 in.WC/100 ft (0.41 Pa/m) You type
Velocity 780.1 fpm (about 4.0 m/s) Tool
Round duct (equivalent diameter) 18 in. (about 457 mm) Tool
Duct height 12 in. (about 305 mm) You type
Duct width 23 in. (about 584 mm) Tool
Equivalent diameter of 12 x 23 in. 17.93 in. Tool
Fluid velocity 785.6 ft/min Tool
Velocity pressure 0.0385 in.WC Tool
Head loss of 12 x 23 in. duct 0.051 in.WC/100 ft Tool

All values are read from McQuay Duct Sizer v6.4. The head loss of the 12 x 23 in. duct is 0.051, slightly above the 0.05 target, because its equivalent diameter is 17.93 in. and not a full 18 in.

Typical Design Values

The values below are typical starting points only. Always follow your project specification and the consultant’s design criteria.

Parameter Typical Value
Friction rate, low-velocity systems 0.05 to 0.1 in.WC per 100 ft (0.41 to 0.82 Pa/m). Lower values give larger, quieter ducts
Main duct velocity, offices and commercial 1,000 to 1,500 fpm (5 to 7.5 m/s)
Branch duct velocity 600 to 1,000 fpm (3 to 5 m/s)
Rectangular duct aspect ratio Up to 4:1 where space allows

Working in L/s? Many Gulf project specifications give airflow in L/s. Multiply L/s by 2.119 to get CFM. For example, 650 L/s is about 1,377 CFM, as used in the example above.

Practical Notes

Point Why It Matters What to Do
Straight duct only The result is friction loss per length of straight duct. It does not include fittings Add elbow, tee, damper and equipment losses before you select the fan static pressure
Standard sizes Fabricators work in fixed size steps Round the result up to the next standard size, typically in 50 mm steps
Internal lining Acoustic lining reduces the clear airflow area Size on the clear internal dimension and add the lining thickness to the sheet metal size
Ceiling space The best size on paper may not fit above the false ceiling Check duct depth with insulation and flanges against the ceiling void before you fix the size

Online Duct Sizer (No Download)

McQuay Duct Sizer is a Windows program, so it will not run on a phone, a tablet or a Mac. For a quick result without downloading anything, use our free online duct sizer. It works in any browser and gives round and rectangular sizes from the same inputs.

For a full walkthrough, read how to size HVAC ducts online.

Download McQuay Duct Sizer v6.4

Click below to download McQuay Duct Sizer. The link will appear after a short wait.

Checking…

After the download, run DuctSizer.exe directly. If the file comes as a zip, extract it first. No setup is needed, so it also runs from a USB drive.

Related Downloads

Frequently Asked Questions

Is McQuay Duct Sizer free?

Yes. It is a free duct sizing tool originally developed by McQuay International, now Daikin Applied. You do not need a licence key or registration.

What is the latest version of McQuay Duct Sizer?

Version 6.4 is the version offered on this page.

Does McQuay Duct Sizer work on Windows 10 and Windows 11?

Yes. It runs on Windows XP through Windows 11, on both 32-bit and 64-bit systems. It is portable, so you run DuctSizer.exe without installing anything.

Is there an online version of McQuay Duct Sizer?

There is no official online version. For browser-based sizing, use the free MEPBase online duct sizer linked above.

Is there a McQuay Duct Sizer Excel sheet?

No. McQuay Duct Sizer is a standalone Windows program, not an Excel file. If you cannot install software, the online duct sizer is the closest alternative.

Can I use McQuay Duct Sizer on Android or iPhone?

No. The download is a Windows program and will not run on Android or iOS. On a phone, use the online tool instead.

What friction rate should I use for duct sizing?

For low-velocity systems, 0.05 to 0.1 in.WC per 100 ft is a typical starting range with the equal friction method. Your project specification may require a different value.

Need another HVAC tool or a fix in this file? Leave a comment below. Stay connected with MEPBase.com for more MEP software, DWG files and AutoCAD add-ons.

MEPBase is not affiliated with Daikin Applied or McQuay. All product names and trademarks belong to their respective owners.

Written byMEPbase Staff