<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>pipe schedule &#8211; MEPBase</title>
	<atom:link href="https://mepbase.com/tag/pipe-schedule/feed/" rel="self" type="application/rss+xml" />
	<link>https://mepbase.com</link>
	<description>Free MEP CAD Blocks, DWG Drawings and Tools</description>
	<lastBuildDate>Sun, 08 Nov 2026 07:12:32 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.5</generator>

<image>
	<url>https://mepbase.com/wp-content/uploads/2026/06/cropped-mepbase-icon-512-32x32.png</url>
	<title>pipe schedule &#8211; MEPBase</title>
	<link>https://mepbase.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Pipe Size Chart: NPS, DN, OD and Schedule 40 &#038; 80 (Inch and mm)</title>
		<link>https://mepbase.com/pipe-size-chart/</link>
					<comments>https://mepbase.com/pipe-size-chart/#respond</comments>
		
		<dc:creator><![CDATA[MEPbase Staff]]></dc:creator>
		<pubDate>Wed, 14 Oct 2026 10:08:16 +0000</pubDate>
				<category><![CDATA[Plumbing]]></category>
		<category><![CDATA[copper tube size]]></category>
		<category><![CDATA[DN]]></category>
		<category><![CDATA[NPS]]></category>
		<category><![CDATA[pipe schedule]]></category>
		<category><![CDATA[pipe size chart]]></category>
		<category><![CDATA[schedule 40]]></category>
		<category><![CDATA[schedule 80]]></category>
		<guid isPermaLink="false">https://mepbase.com/?p=1175</guid>

					<description><![CDATA[Need the outside diameter of a 2 inch pipe, or the inside diameter of Schedule 80? This pipe size chart lists every ... <a title="Pipe Size Chart: NPS, DN, OD and Schedule 40 &#038; 80 (Inch and mm)" class="read-more" href="https://mepbase.com/pipe-size-chart/" aria-label="Read more about Pipe Size Chart: NPS, DN, OD and Schedule 40 &#038; 80 (Inch and mm)">Read more</a>]]></description>
										<content:encoded><![CDATA[<p>Need the outside diameter of a 2 inch pipe, or the inside diameter of Schedule 80? This <strong>pipe size chart</strong> lists every nominal pipe size from ⅛ to 24 inches with its DN equivalent, outside diameter, wall thickness, inside diameter and weight for Schedule 40 and Schedule 80, in inches and millimetres, plus copper tube sizes. Download the full chart as a free PDF at the end.</p>
<p><strong>Quick answer:</strong> A pipe&#8217;s <strong>nominal size (NPS) is not its actual diameter</strong>. Up to 12 inches the outside diameter is larger than the nominal size (a 1 inch pipe is 1.315 in / 33.4 mm OD); from 14 inches up the OD equals the nominal size. The schedule (40, 80) only changes the wall thickness and inside diameter.</p>
<p><img fetchpriority="high" decoding="async" class="aligncenter size-full" src="https://mepbase.com/wp-content/uploads/2026/10/pipe-size-chart-updated.webp" alt="Pipe size chart showing NPS, DN and OD with a 4 inch DN100 pipe of 114.3 mm OD, schedule 40 and 80 in inch and mm" width="1200" height="675" /></p>
<p><strong>In this guide</strong></p>
<ol>
<li><a href="#chart-in">Pipe size chart in inches</a></li>
<li><a href="#chart-mm">Pipe size chart in mm with weight</a></li>
<li><a href="#nps">NPS, DN and OD explained</a></li>
<li><a href="#schedule">What pipe schedule means</a></li>
<li><a href="#pvc">PVC pipe sizes</a></li>
<li><a href="#copper">Copper tube size chart</a></li>
<li><a href="#download">Download the PDF chart</a></li>
<li><a href="#faq">FAQ</a></li>
</ol>
<h2 id="chart-in">Pipe Size Chart (Inches): Schedule 40 and 80</h2>
<table>
<thead>
<tr>
<th>NPS (in)</th>
<th>OD (in)</th>
<th>Sch 40 wall</th>
<th>Sch 40 ID</th>
<th>Sch 80 wall</th>
<th>Sch 80 ID</th>
</tr>
</thead>
<tbody>
<tr>
<td><strong>⅛</strong></td>
<td>0.405</td>
<td>0.068</td>
<td>0.269</td>
<td>0.095</td>
<td>0.215</td>
</tr>
<tr>
<td><strong>¼</strong></td>
<td>0.540</td>
<td>0.088</td>
<td>0.364</td>
<td>0.119</td>
<td>0.302</td>
</tr>
<tr>
<td><strong>⅜</strong></td>
<td>0.675</td>
<td>0.091</td>
<td>0.493</td>
<td>0.126</td>
<td>0.423</td>
</tr>
<tr>
<td><strong>½</strong></td>
<td>0.840</td>
<td>0.109</td>
<td>0.622</td>
<td>0.147</td>
<td>0.546</td>
</tr>
<tr>
<td><strong>¾</strong></td>
<td>1.050</td>
<td>0.113</td>
<td>0.824</td>
<td>0.154</td>
<td>0.742</td>
</tr>
<tr>
<td><strong>1</strong></td>
<td>1.315</td>
<td>0.133</td>
<td>1.049</td>
<td>0.179</td>
<td>0.957</td>
</tr>
<tr>
<td><strong>1¼</strong></td>
<td>1.660</td>
<td>0.140</td>
<td>1.380</td>
<td>0.191</td>
<td>1.278</td>
</tr>
<tr>
<td><strong>1½</strong></td>
<td>1.900</td>
<td>0.145</td>
<td>1.610</td>
<td>0.200</td>
<td>1.500</td>
</tr>
<tr>
<td><strong>2</strong></td>
<td>2.375</td>
<td>0.154</td>
<td>2.067</td>
<td>0.218</td>
<td>1.939</td>
</tr>
<tr>
<td><strong>2½</strong></td>
<td>2.875</td>
<td>0.203</td>
<td>2.469</td>
<td>0.276</td>
<td>2.323</td>
</tr>
<tr>
<td><strong>3</strong></td>
<td>3.500</td>
<td>0.216</td>
<td>3.068</td>
<td>0.300</td>
<td>2.900</td>
</tr>
<tr>
<td><strong>4</strong></td>
<td>4.500</td>
<td>0.237</td>
<td>4.026</td>
<td>0.337</td>
<td>3.826</td>
</tr>
<tr>
<td><strong>5</strong></td>
<td>5.563</td>
<td>0.258</td>
<td>5.047</td>
<td>0.375</td>
<td>4.813</td>
</tr>
<tr>
<td><strong>6</strong></td>
<td>6.625</td>
<td>0.280</td>
<td>6.065</td>
<td>0.432</td>
<td>5.761</td>
</tr>
<tr>
<td><strong>8</strong></td>
<td>8.625</td>
<td>0.322</td>
<td>7.981</td>
<td>0.500</td>
<td>7.625</td>
</tr>
<tr>
<td><strong>10</strong></td>
<td>10.750</td>
<td>0.365</td>
<td>10.020</td>
<td>0.593</td>
<td>9.564</td>
</tr>
<tr>
<td><strong>12</strong></td>
<td>12.750</td>
<td>0.406</td>
<td>11.938</td>
<td>0.687</td>
<td>11.376</td>
</tr>
<tr>
<td><strong>14</strong></td>
<td>14.000</td>
<td>0.437</td>
<td>13.126</td>
<td>0.750</td>
<td>12.500</td>
</tr>
<tr>
<td><strong>16</strong></td>
<td>16.000</td>
<td>0.500</td>
<td>15.000</td>
<td>0.843</td>
<td>14.314</td>
</tr>
<tr>
<td><strong>18</strong></td>
<td>18.000</td>
<td>0.562</td>
<td>16.876</td>
<td>0.937</td>
<td>16.126</td>
</tr>
<tr>
<td><strong>20</strong></td>
<td>20.000</td>
<td>0.593</td>
<td>18.814</td>
<td>1.031</td>
<td>17.938</td>
</tr>
<tr>
<td><strong>24</strong></td>
<td>24.000</td>
<td>0.687</td>
<td>22.626</td>
<td>1.218</td>
<td>21.564</td>
</tr>
</tbody>
</table>
<p><em>Steel pipe dimensions to ASME B36.10M. All values in inches.</em></p>
<h2 id="chart-mm">Pipe Size Chart (mm) with DN and Weight</h2>
<table>
<thead>
<tr>
<th>NPS</th>
<th>DN</th>
<th>OD (mm)</th>
<th>Sch 40 wall</th>
<th>Sch 40 ID</th>
<th>Sch 40 kg/m</th>
<th>Sch 80 wall</th>
<th>Sch 80 ID</th>
<th>Sch 80 kg/m</th>
</tr>
</thead>
<tbody>
<tr>
<td><strong>⅛</strong></td>
<td>DN6</td>
<td>10.3</td>
<td>1.73</td>
<td>6.8</td>
<td>0.36</td>
<td>2.41</td>
<td>5.5</td>
<td>0.47</td>
</tr>
<tr>
<td><strong>¼</strong></td>
<td>DN8</td>
<td>13.7</td>
<td>2.24</td>
<td>9.2</td>
<td>0.63</td>
<td>3.02</td>
<td>7.7</td>
<td>0.80</td>
</tr>
<tr>
<td><strong>⅜</strong></td>
<td>DN10</td>
<td>17.1</td>
<td>2.31</td>
<td>12.5</td>
<td>0.85</td>
<td>3.20</td>
<td>10.7</td>
<td>1.10</td>
</tr>
<tr>
<td><strong>½</strong></td>
<td>DN15</td>
<td>21.3</td>
<td>2.77</td>
<td>15.8</td>
<td>1.27</td>
<td>3.73</td>
<td>13.9</td>
<td>1.62</td>
</tr>
<tr>
<td><strong>¾</strong></td>
<td>DN20</td>
<td>26.7</td>
<td>2.87</td>
<td>20.9</td>
<td>1.68</td>
<td>3.91</td>
<td>18.8</td>
<td>2.20</td>
</tr>
<tr>
<td><strong>1</strong></td>
<td>DN25</td>
<td>33.4</td>
<td>3.38</td>
<td>26.6</td>
<td>2.50</td>
<td>4.55</td>
<td>24.3</td>
<td>3.23</td>
</tr>
<tr>
<td><strong>1¼</strong></td>
<td>DN32</td>
<td>42.2</td>
<td>3.56</td>
<td>35.1</td>
<td>3.39</td>
<td>4.85</td>
<td>32.5</td>
<td>4.46</td>
</tr>
<tr>
<td><strong>1½</strong></td>
<td>DN40</td>
<td>48.3</td>
<td>3.68</td>
<td>40.9</td>
<td>4.05</td>
<td>5.08</td>
<td>38.1</td>
<td>5.41</td>
</tr>
<tr>
<td><strong>2</strong></td>
<td>DN50</td>
<td>60.3</td>
<td>3.91</td>
<td>52.5</td>
<td>5.44</td>
<td>5.54</td>
<td>49.3</td>
<td>7.48</td>
</tr>
<tr>
<td><strong>2½</strong></td>
<td>DN65</td>
<td>73.0</td>
<td>5.16</td>
<td>62.7</td>
<td>8.63</td>
<td>7.01</td>
<td>59.0</td>
<td>11.41</td>
</tr>
<tr>
<td><strong>3</strong></td>
<td>DN80</td>
<td>88.9</td>
<td>5.49</td>
<td>77.9</td>
<td>11.28</td>
<td>7.62</td>
<td>73.7</td>
<td>15.27</td>
</tr>
<tr>
<td><strong>4</strong></td>
<td>DN100</td>
<td>114.3</td>
<td>6.02</td>
<td>102.3</td>
<td>16.07</td>
<td>8.56</td>
<td>97.2</td>
<td>22.32</td>
</tr>
<tr>
<td><strong>5</strong></td>
<td>DN125</td>
<td>141.3</td>
<td>6.55</td>
<td>128.2</td>
<td>21.77</td>
<td>9.52</td>
<td>122.3</td>
<td>30.95</td>
</tr>
<tr>
<td><strong>6</strong></td>
<td>DN150</td>
<td>168.3</td>
<td>7.11</td>
<td>154.1</td>
<td>28.26</td>
<td>10.97</td>
<td>146.3</td>
<td>42.56</td>
</tr>
<tr>
<td><strong>8</strong></td>
<td>DN200</td>
<td>219.1</td>
<td>8.18</td>
<td>202.7</td>
<td>42.53</td>
<td>12.70</td>
<td>193.7</td>
<td>64.63</td>
</tr>
<tr>
<td><strong>10</strong></td>
<td>DN250</td>
<td>273.1</td>
<td>9.27</td>
<td>254.5</td>
<td>60.30</td>
<td>15.06</td>
<td>242.9</td>
<td>95.82</td>
</tr>
<tr>
<td><strong>12</strong></td>
<td>DN300</td>
<td>323.8</td>
<td>10.31</td>
<td>303.2</td>
<td>79.73</td>
<td>17.45</td>
<td>289.0</td>
<td>131.84</td>
</tr>
<tr>
<td><strong>14</strong></td>
<td>DN350</td>
<td>355.6</td>
<td>11.10</td>
<td>333.4</td>
<td>94.29</td>
<td>19.05</td>
<td>317.5</td>
<td>158.09</td>
</tr>
<tr>
<td><strong>16</strong></td>
<td>DN400</td>
<td>406.4</td>
<td>12.70</td>
<td>381.0</td>
<td>123.29</td>
<td>21.41</td>
<td>363.6</td>
<td>203.27</td>
</tr>
<tr>
<td><strong>18</strong></td>
<td>DN450</td>
<td>457.2</td>
<td>14.27</td>
<td>428.7</td>
<td>155.91</td>
<td>23.80</td>
<td>409.6</td>
<td>254.34</td>
</tr>
<tr>
<td><strong>20</strong></td>
<td>DN500</td>
<td>508.0</td>
<td>15.06</td>
<td>477.9</td>
<td>183.08</td>
<td>26.19</td>
<td>455.6</td>
<td>311.12</td>
</tr>
<tr>
<td><strong>24</strong></td>
<td>DN600</td>
<td>609.6</td>
<td>17.45</td>
<td>574.7</td>
<td>254.79</td>
<td>30.94</td>
<td>547.7</td>
<td>441.43</td>
</tr>
</tbody>
</table>
<p><em>Wall and ID in mm. Weight is plain-end carbon steel: lb/ft = 10.69 × (OD − t) × t, converted to kg/m.</em></p>
<p><strong>Look up any size and schedule:</strong> interactive chart with Schedule 40, 80 and 160 in inches or millimetres in the <a href="https://tools.mepbase.com/pipe-schedule-reference">Pipe Schedule Reference →</a></p>
<h2 id="nps">NPS, DN and OD: Why a 1 Inch Pipe Is Not 1 Inch</h2>
<p>Pipe sizes started as the approximate <em>inside</em> diameter of early iron pipe. When stronger steel allowed thinner walls, the outside diameter was kept the same so fittings still matched, and the inside diameter changed instead. The result is today&#8217;s system:</p>
<ul>
<li><strong>NPS (Nominal Pipe Size)</strong> is a name in inches, not a measurement.</li>
<li><strong>OD (outside diameter)</strong> is fixed for each NPS, whatever the schedule. Up to NPS 12 it is larger than the nominal size; from NPS 14 it equals the nominal size.</li>
<li><strong>DN (Diamètre Nominal)</strong> is the metric name used in ISO and EN standards: DN25 = NPS 1, DN50 = NPS 2, DN100 = NPS 4.</li>
<li><strong>ID (inside diameter)</strong> = OD − 2 × wall thickness, and depends on the schedule.</li>
</ul>
<p><strong>Common mix-up on site:</strong> DN100 pipe is not 100 mm outside diameter: it is 114.3 mm OD. Always check the OD when ordering fittings, clamps, sleeves and insulation.</p>
<h2 id="schedule">What Pipe Schedule Means</h2>
<p>The schedule number sets the wall thickness for each size. Higher schedule = thicker wall = higher pressure rating and smaller bore. Schedule 40 is the everyday standard for water, fire and HVAC piping; Schedule 80 is used for higher pressure, threaded joints in larger sizes, and where corrosion allowance is needed. Up to NPS 10, Schedule 40 is the same as the older <strong>STD (standard weight)</strong> class, and up to NPS 8 Schedule 80 matches <strong>XS (extra strong)</strong>.</p>
<h2 id="pvc">PVC Pipe Sizes</h2>
<p>PVC Schedule 40 and Schedule 80 pressure pipe (ASTM D1785) is made to the <strong>same outside diameters</strong> as steel pipe, and its minimum wall thicknesses follow the same schedule table. That is why the chart above also works as a <strong>PVC pipe size chart</strong> for Schedule 40 and 80. Metric PVC and uPVC pipe (ISO 1452, EN 1401 drainage) is different: it is named by its actual outside diameter in mm, for example 110 mm or 160 mm, with the wall set by the pressure class.</p>
<h2 id="copper">Copper Tube Size Chart</h2>
<p>Copper water tube (ASTM B88) uses a different rule: the <strong>outside diameter is the nominal size plus ⅛ inch</strong>. Type K has the thickest wall, Type L is the usual choice for domestic water, and Type M is the thinnest.</p>
<table>
<thead>
<tr>
<th>Nominal (in)</th>
<th>OD (in)</th>
<th>OD (mm)</th>
<th>Type K wall</th>
<th>Type L wall</th>
<th>Type M wall</th>
</tr>
</thead>
<tbody>
<tr>
<td><strong>½</strong></td>
<td>0.625</td>
<td>15.88</td>
<td>0.049</td>
<td>0.040</td>
<td>0.028</td>
</tr>
<tr>
<td><strong>¾</strong></td>
<td>0.875</td>
<td>22.23</td>
<td>0.065</td>
<td>0.045</td>
<td>0.032</td>
</tr>
<tr>
<td><strong>1</strong></td>
<td>1.125</td>
<td>28.58</td>
<td>0.065</td>
<td>0.050</td>
<td>0.035</td>
</tr>
<tr>
<td><strong>1¼</strong></td>
<td>1.375</td>
<td>34.93</td>
<td>0.065</td>
<td>0.055</td>
<td>0.042</td>
</tr>
<tr>
<td><strong>1½</strong></td>
<td>1.625</td>
<td>41.28</td>
<td>0.072</td>
<td>0.060</td>
<td>0.049</td>
</tr>
<tr>
<td><strong>2</strong></td>
<td>2.125</td>
<td>53.98</td>
<td>0.083</td>
<td>0.070</td>
<td>0.058</td>
</tr>
<tr>
<td><strong>2½</strong></td>
<td>2.625</td>
<td>66.68</td>
<td>0.095</td>
<td>0.080</td>
<td>0.065</td>
</tr>
<tr>
<td><strong>3</strong></td>
<td>3.125</td>
<td>79.38</td>
<td>0.109</td>
<td>0.090</td>
<td>0.072</td>
</tr>
<tr>
<td><strong>4</strong></td>
<td>4.125</td>
<td>104.78</td>
<td>0.134</td>
<td>0.110</td>
<td>0.095</td>
</tr>
</tbody>
</table>
<p><em>Wall thickness in inches.</em></p>
<h2 id="download">Download the Pipe Size Chart PDF</h2>
<p>The free PDF has the full steel chart (inches and mm, Schedule 40 and 80 with weights), the copper tube chart and an NPS to DN table, on two printable A4 pages.</p>
<div id="mbdl_6423" class="mb-dl" data-href="https://mepbase.com/files/pipe-size-chart-mepbase.pdf" data-wait="10">
  <div class="adsbox ad-banner ads ad-placement" style="position:absolute;height:1px;width:1px;left:-9999px;top:-9999px;" aria-hidden="true">&nbsp;</div>
  <div class="mb-dl-card">

    <div class="mb-dl-checking"><p class="mb-dl-msg">Checking…</p></div>

    <div class="mb-dl-blocked" style="display:none;">
      <div class="mb-dl-ico">🚫</div>
      <p class="mb-dl-title">Ad blocker detected</p>
      <p class="mb-dl-text">We keep this resource <strong>free</strong> with the help of ads. Please <strong>whitelist this website</strong> so we can continue publishing useful DWG drawings and CAD content.</p>
      <p class="mb-dl-text mb-dl-small">After whitelisting, please refresh the page to continue.</p>
      <button type="button" class="mb-dl-btn" onclick="location.reload()">🔄 I have whitelisted — Refresh</button>
    </div>

    <div class="mb-dl-start" style="display:none;">
      <button type="button" class="mb-dl-btn mb-dl-go mb-dl-startbtn">Download Pipe Size Chart PDF (Free)</button>
    </div>

    <div class="mb-dl-wait" style="display:none;">
      <p class="mb-dl-title">Your download is getting ready</p>
      <div class="mb-dl-count"><span class="mb-dl-sec">10</span></div>
      <p class="mb-dl-text mb-dl-small">Please wait, your download button will appear shortly…</p>
    </div>

    <div class="mb-dl-ready" style="display:none;">
      <a class="mb-dl-btn mb-dl-go mb-dl-link" href="#" target="_blank" rel="nofollow noopener">Download Pipe Size Chart PDF (Free)</a>
    </div>

  </div>
</div>
<style>
.mb-dl{max-width:520px;margin:22px auto;font-family:-apple-system,BlinkMacSystemFont,"Segoe UI",Roboto,Arial,sans-serif;text-align:center}
.mb-dl,.mb-dl *{text-align:center !important}
.mb-dl .mb-dl-card{background:#f4f6f9;border:1px solid #dde2e8;border-radius:14px;padding:26px 22px}
.mb-dl .mb-dl-title{font-size:19px;font-weight:700;color:#1c2530;margin:0 0 8px}
.mb-dl .mb-dl-msg{font-size:15px;color:#667085;margin:0}
.mb-dl .mb-dl-text{font-size:14.5px;color:#33414f;line-height:1.6;margin:0 0 10px}
.mb-dl .mb-dl-small{font-size:13px;color:#667085}
.mb-dl .mb-dl-ico{font-size:40px;margin-bottom:6px}
.mb-dl .mb-dl-count{width:84px;height:84px;border-radius:50%;background:#1565c0;color:#fff !important;font-size:34px;font-weight:800;display:flex;align-items:center;justify-content:center;margin:6px auto 12px}
.mb-dl .mb-dl-btn,
.mb-dl a.mb-dl-btn,
.mb-dl a.mb-dl-btn:link,
.mb-dl a.mb-dl-btn:visited{display:inline-block;background:#1565c0;color:#fff !important;font-size:16px;font-weight:700;text-decoration:none !important;border:0;cursor:pointer;padding:14px 30px;border-radius:10px;margin-top:6px}
.mb-dl .mb-dl-btn:hover,
.mb-dl a.mb-dl-btn:hover,
.mb-dl a.mb-dl-btn:focus,
.mb-dl a.mb-dl-btn:active,
.mb-dl button.mb-dl-btn:hover{background:#0d4ea0 !important;color:#fff !important;text-decoration:none !important}
.mb-dl .mb-dl-go{box-shadow:0 6px 18px rgba(21,101,192,.28)}
</style>
<script>
(function(){
  function init(root){
    var href=root.getAttribute('data-href');
    var wait=parseInt(root.getAttribute('data-wait'),10)||15;
    var checking=root.querySelector('.mb-dl-checking');
    var blocked=root.querySelector('.mb-dl-blocked');
    var startBox=root.querySelector('.mb-dl-start');
    var startBtn=root.querySelector('.mb-dl-startbtn');
    var waitEl=root.querySelector('.mb-dl-wait');
    var ready=root.querySelector('.mb-dl-ready');
    var secEl=root.querySelector('.mb-dl-sec');
    var link=root.querySelector('.mb-dl-link');
    function show(el){[checking,blocked,startBox,waitEl,ready].forEach(function(x){x.style.display='none';});el.style.display='block';}

    function countdown(){
      show(waitEl); var s=wait; secEl.textContent=s;
      var t=setInterval(function(){
        s--; secEl.textContent=s;
        if(s<=0){
          clearInterval(t);
          link.href=href;
          show(ready);
          // auto-start download via hidden iframe (no popup, no new tab)
          try{
            var ifr=document.createElement('iframe');
            ifr.style.display='none';
            ifr.src=href;
            document.body.appendChild(ifr);
          }catch(e){}
        }
      },1000);
    }

    startBtn.addEventListener('click',function(){ countdown(); });

    function detect(){
      var bait=root.querySelector('.adsbox');
      var cssBlock=(bait.offsetHeight===0||bait.offsetParent===null||bait.clientHeight===0);
      var done=false;
      function decide(b){ if(done)return; done=true; (b||cssBlock)?show(blocked):show(startBox); }
      try{
        var sc=document.createElement('script');
        sc.src='https://pagead2.googlesyndication.com/pagead/js/adsbygoogle.js';
        sc.onload=function(){decide(false);};
        sc.onerror=function(){decide(true);};
        document.body.appendChild(sc);
        setTimeout(function(){decide(cssBlock);},2500);
      }catch(e){decide(true);}
    }
    setTimeout(detect,400);
  }
  function boot(){var all=document.querySelectorAll('.mb-dl');for(var i=0;i<all.length;i++){init(all[i]);}}
  if(document.readyState!=='loading'){boot();}else{document.addEventListener('DOMContentLoaded',boot);}
})();
</script>

<p>Drafting pipe sections? The DWG has every size from NPS ⅛ to 24 as a true-scale block (outside and inside circles, in mm) for Schedule 40 and 80, named MB_PIPE_DN50_SCH40 and so on.</p>
<div id="mbdl_9010" class="mb-dl" data-href="https://mepbase.com/files/pipe-sections-sch40-sch80-mepbase.dwg" data-wait="10">
  <div class="adsbox ad-banner ads ad-placement" style="position:absolute;height:1px;width:1px;left:-9999px;top:-9999px;" aria-hidden="true">&nbsp;</div>
  <div class="mb-dl-card">

    <div class="mb-dl-checking"><p class="mb-dl-msg">Checking…</p></div>

    <div class="mb-dl-blocked" style="display:none;">
      <div class="mb-dl-ico">🚫</div>
      <p class="mb-dl-title">Ad blocker detected</p>
      <p class="mb-dl-text">We keep this resource <strong>free</strong> with the help of ads. Please <strong>whitelist this website</strong> so we can continue publishing useful DWG drawings and CAD content.</p>
      <p class="mb-dl-text mb-dl-small">After whitelisting, please refresh the page to continue.</p>
      <button type="button" class="mb-dl-btn" onclick="location.reload()">🔄 I have whitelisted — Refresh</button>
    </div>

    <div class="mb-dl-start" style="display:none;">
      <button type="button" class="mb-dl-btn mb-dl-go mb-dl-startbtn">Download Pipe Sections DWG (Free)</button>
    </div>

    <div class="mb-dl-wait" style="display:none;">
      <p class="mb-dl-title">Your download is getting ready</p>
      <div class="mb-dl-count"><span class="mb-dl-sec">10</span></div>
      <p class="mb-dl-text mb-dl-small">Please wait, your download button will appear shortly…</p>
    </div>

    <div class="mb-dl-ready" style="display:none;">
      <a class="mb-dl-btn mb-dl-go mb-dl-link" href="#" target="_blank" rel="nofollow noopener">Download Pipe Sections DWG (Free)</a>
    </div>

  </div>
</div>

<div class="mb-faq">
<h2 id="faq">Frequently Asked Questions</h2>
<details open="">
<summary>What is the outside diameter of a 1 inch pipe?</summary>
<div class="mb-faq-a">
<p>1.315 inches (33.4 mm) for steel and PVC Schedule 40 or 80. The nominal size of 1 inch is a name, not a measurement.</p>
</div>
</details>
<details>
<summary>What is the difference between NPS and DN?</summary>
<div class="mb-faq-a">
<p>They are two names for the same pipe size. NPS is the inch-based name used in North America (NPS 2), DN is the metric name used in ISO and EN standards (DN50). The pipe has the same outside diameter.</p>
</div>
</details>
<details>
<summary>What is the difference between Schedule 40 and Schedule 80?</summary>
<div class="mb-faq-a">
<p>Schedule 80 has a thicker wall than Schedule 40 for the same size, so it handles higher pressure but has a smaller inside diameter. The outside diameter is the same, so both use the same fittings.</p>
</div>
</details>
<details>
<summary>Are PVC and steel pipe sizes the same?</summary>
<div class="mb-faq-a">
<p>For Schedule 40 and 80 PVC pressure pipe to ASTM D1785, yes: the outside diameters and minimum walls match the steel pipe schedule. Metric PVC pipe is named by its outside diameter in mm and does not follow the steel chart.</p>
</div>
</details>
<details>
<summary>When does pipe OD equal the nominal size?</summary>
<div class="mb-faq-a">
<p>From NPS 14 upwards. A 14 inch pipe has a 14.000 inch outside diameter, while every size up to 12 inches has an OD larger than its nominal size.</p>
</div>
</details>
</div>
<h2>Related Downloads and Tools</h2>
<ul>
<li><a href="https://tools.mepbase.com/pipe-schedule-reference">Pipe Schedule Reference (interactive)</a></li>
<li><a href="https://tools.mepbase.com/water-pipe-pressure-drop-calculator">Water Pipe Pressure Drop Calculator</a></li>
<li><a href="https://tools.mepbase.com/material-weight-calculator">Material Weight Calculator</a></li>
<li><a href="https://mepbase.com/black-steel-pipe-dynamic-block-dwg/">Black steel pipe dynamic block (DWG)</a></li>
<li><a href="https://mepbase.com/pipe-fitting-cad-blocks-free-download/">Pipe fitting CAD blocks</a></li>
<li><a href="https://mepbase.com/sprinkler-pipe-size-chart/">Sprinkler pipe size chart (NFPA 13)</a></li>
</ul>
<p><em>Dimensions per ASME B36.10M and ASTM B88; confirm against the manufacturer&#8217;s data for final design.</em></p>
]]></content:encoded>
					
					<wfw:commentRss>https://mepbase.com/pipe-size-chart/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Sprinkler Pipe Size Chart: How Many Sprinklers per Pipe Size (NFPA 13)</title>
		<link>https://mepbase.com/sprinkler-pipe-size-chart/</link>
					<comments>https://mepbase.com/sprinkler-pipe-size-chart/#respond</comments>
		
		<dc:creator><![CDATA[MEPbase Staff]]></dc:creator>
		<pubDate>Mon, 12 Oct 2026 14:05:16 +0000</pubDate>
				<category><![CDATA[Fire Fighting]]></category>
		<category><![CDATA[branch line]]></category>
		<category><![CDATA[cross main]]></category>
		<category><![CDATA[fire sprinkler]]></category>
		<category><![CDATA[NFPA 13]]></category>
		<category><![CDATA[pipe schedule]]></category>
		<category><![CDATA[sprinkler pipe sizing]]></category>
		<guid isPermaLink="false">https://mepbase.com/?p=1157</guid>

					<description><![CDATA[Complete NFPA 13 sprinkler pipe size chart for light and ordinary hazard, steel and copper. 2 sprinklers need a 1 inch pipe; see branch line and cross main sizing examples.]]></description>
										<content:encoded><![CDATA[<p><img decoding="async" class="aligncenter size-full wp-image-1158" src="https://mepbase.com/wp-content/uploads/2026/10/sprinkler-pipe-size-chart.webp" alt="Sprinkler pipe size chart showing an 8-sprinkler branch line sized 2, 2, 2, 1½, 1½, 1¼, 1 and 1 inch, with NFPA 13 light and ordinary hazard limits for 1 to 3 inch steel pipe" width="1200" height="675" srcset="https://mepbase.com/wp-content/uploads/2026/10/sprinkler-pipe-size-chart.webp 1200w, https://mepbase.com/wp-content/uploads/2026/10/sprinkler-pipe-size-chart-300x169.webp 300w, https://mepbase.com/wp-content/uploads/2026/10/sprinkler-pipe-size-chart-1024x576.webp 1024w, https://mepbase.com/wp-content/uploads/2026/10/sprinkler-pipe-size-chart-768x432.webp 768w, https://mepbase.com/wp-content/uploads/2026/10/sprinkler-pipe-size-chart-390x220.webp 390w" sizes="(max-width: 1200px) 100vw, 1200px" /></p>
<p>How many sprinklers can a 1 inch pipe feed? What size pipe do you need for 2 sprinklers, 10 sprinklers or a whole floor? This guide gives the complete <strong>sprinkler pipe size chart</strong> from the NFPA 13 pipe schedule method, shows how to size a branch line and cross main step by step, and explains when the table is allowed and when you need a hydraulic calculation instead.</p>
<p><strong>Quick answer:</strong> 2 sprinklers need a 1 inch (DN25) pipe in both light and ordinary hazard. 1¼ inch takes 3 sprinklers, 1½ inch takes 5 and 2 inch takes 10 in steel pipe. Above 2 inch the limit depends on the hazard class.</p>
<p><strong>Key takeaways</strong></p>
<ul>
<li>Count the sprinklers <strong>downstream</strong> of each pipe, starting from the dead end.</li>
<li>Up to 2 inch, light and ordinary hazard use the <strong>same</strong> limits.</li>
<li>From 2½ inch upwards ordinary hazard allows <strong>fewer</strong> sprinklers per pipe.</li>
<li>The pipe schedule is only for light and ordinary hazard, mostly small systems. Larger new systems need a hydraulic calculation.</li>
</ul>
<p><strong>In this guide</strong></p>
<ol>
<li><a href="#chart">Sprinkler pipe size chart (NFPA 13)</a></li>
<li><a href="#lookup">Pipe size for any number of sprinklers</a></li>
<li><a href="#why">Why 2 sprinklers need a 1 inch pipe</a></li>
<li><a href="#branch">Worked example 1: branch line</a></li>
<li><a href="#crossmain">Worked example 2: cross main</a></li>
<li><a href="#coverage">Coverage area per sprinkler</a></li>
<li><a href="#when">When the pipe schedule is allowed</a></li>
<li><a href="#abovebelow">Sprinklers above and below a ceiling</a></li>
<li><a href="#mistakes">Common mistakes</a></li>
<li><a href="#faq">FAQ</a></li>
</ol>
<h2 id="chart">Sprinkler Pipe Size Chart (NFPA 13 Pipe Schedule)</h2>
<p>The pipe schedule method sizes each pipe by counting how many sprinklers are downstream of it. Every pipe must be at least the size the table gives for that number of sprinklers.</p>
<h3>Light Hazard</h3>
<p>Offices, schools, hospitals, hotels, residential areas, restaurant seating areas, churches.</p>
<table>
<thead>
<tr>
<th>Pipe size</th>
<th>Metric</th>
<th>Max sprinklers, steel</th>
<th>Max sprinklers, copper</th>
</tr>
</thead>
<tbody>
<tr>
<td><strong>1 in</strong></td>
<td>DN25</td>
<td>2</td>
<td>2</td>
</tr>
<tr>
<td><strong>1¼ in</strong></td>
<td>DN32</td>
<td>3</td>
<td>3</td>
</tr>
<tr>
<td><strong>1½ in</strong></td>
<td>DN40</td>
<td>5</td>
<td>5</td>
</tr>
<tr>
<td><strong>2 in</strong></td>
<td>DN50</td>
<td>10</td>
<td>12</td>
</tr>
<tr>
<td><strong>2½ in</strong></td>
<td>DN65</td>
<td>30</td>
<td>40</td>
</tr>
<tr>
<td><strong>3 in</strong></td>
<td>DN80</td>
<td>60</td>
<td>65</td>
</tr>
<tr>
<td><strong>3½ in</strong></td>
<td>DN90</td>
<td>100</td>
<td>115</td>
</tr>
<tr>
<td><strong>4 in and larger</strong></td>
<td>DN100+</td>
<td>Limited by the maximum floor area per system</td>
<td>—</td>
</tr>
</tbody>
</table>
<h3>Ordinary Hazard (Group 1 and Group 2)</h3>
<p>Car parks, laundries, restaurant kitchens, mechanical rooms, retail shops, workshops, light storage.</p>
<table>
<thead>
<tr>
<th>Pipe size</th>
<th>Metric</th>
<th>Max sprinklers, steel</th>
<th>Max sprinklers, copper</th>
</tr>
</thead>
<tbody>
<tr>
<td><strong>1 in</strong></td>
<td>DN25</td>
<td>2</td>
<td>2</td>
</tr>
<tr>
<td><strong>1¼ in</strong></td>
<td>DN32</td>
<td>3</td>
<td>3</td>
</tr>
<tr>
<td><strong>1½ in</strong></td>
<td>DN40</td>
<td>5</td>
<td>5</td>
</tr>
<tr>
<td><strong>2 in</strong></td>
<td>DN50</td>
<td>10</td>
<td>12</td>
</tr>
<tr>
<td><strong>2½ in</strong></td>
<td>DN65</td>
<td><strong>20</strong></td>
<td><strong>25</strong></td>
</tr>
<tr>
<td><strong>3 in</strong></td>
<td>DN80</td>
<td><strong>40</strong></td>
<td><strong>45</strong></td>
</tr>
<tr>
<td><strong>3½ in</strong></td>
<td>DN90</td>
<td><strong>65</strong></td>
<td><strong>75</strong></td>
</tr>
<tr>
<td><strong>4 in</strong></td>
<td>DN100</td>
<td>100</td>
<td>115</td>
</tr>
<tr>
<td><strong>5 in</strong></td>
<td>DN125</td>
<td>160</td>
<td>180</td>
</tr>
<tr>
<td><strong>6 in</strong></td>
<td>DN150</td>
<td>275</td>
<td>300</td>
</tr>
</tbody>
</table>
<p><strong>Watch out:</strong> Up to 2 inch both hazard classes are identical. The difference starts at 2½ inch, where light hazard allows 30 sprinklers but ordinary hazard only 20 (shown in bold). Using the light hazard numbers in a car park or kitchen is one of the most common reasons for a rejected submittal.</p>
<h2 id="lookup">Pipe Size for Any Number of Sprinklers</h2>
<p>Turned around, the table gives the minimum steel pipe size for any number of sprinklers:</p>
<table>
<thead>
<tr>
<th>Sprinklers fed</th>
<th>Light hazard</th>
<th>Ordinary hazard</th>
</tr>
</thead>
<tbody>
<tr>
<td><strong>1–2</strong></td>
<td>1 in (DN25)</td>
<td>1 in (DN25)</td>
</tr>
<tr>
<td><strong>3</strong></td>
<td>1¼ in (DN32)</td>
<td>1¼ in (DN32)</td>
</tr>
<tr>
<td><strong>4–5</strong></td>
<td>1½ in (DN40)</td>
<td>1½ in (DN40)</td>
</tr>
<tr>
<td><strong>6–10</strong></td>
<td>2 in (DN50)</td>
<td>2 in (DN50)</td>
</tr>
<tr>
<td><strong>11–20</strong></td>
<td>2½ in (DN65)</td>
<td>2½ in (DN65)</td>
</tr>
<tr>
<td><strong>21–30</strong></td>
<td>2½ in (DN65)</td>
<td><strong>3 in (DN80)</strong></td>
</tr>
<tr>
<td><strong>31–40</strong></td>
<td>3 in (DN80)</td>
<td>3 in (DN80)</td>
</tr>
<tr>
<td><strong>41–60</strong></td>
<td>3 in (DN80)</td>
<td><strong>3½ in (DN90)</strong></td>
</tr>
<tr>
<td><strong>61–65</strong></td>
<td>3½ in (DN90)</td>
<td>3½ in (DN90)</td>
</tr>
<tr>
<td><strong>66–100</strong></td>
<td>3½ in (DN90)</td>
<td><strong>4 in (DN100)</strong></td>
</tr>
</tbody>
</table>
<p><strong>Site tip:</strong> In the Gulf many contractors avoid 3½ inch (DN90) because fittings are hard to find and use 4 inch (DN100) instead. That is always allowed: the table gives the <em>minimum</em> size.</p>
<h2 id="why">Why 2 Sprinklers Need a 1 Inch Pipe</h2>
<p>The table is not arbitrary. Take two standard K5.6 sprinklers flowing at 10 psi:</p>
<pre>q = K × √P = 5.6 × √10 = 17.7 gpm (67 L/min) per sprinkler
Q = 2 × 17.7 = 35.4 gpm (134 L/min)</pre>
<p>In 1 inch Schedule 40 steel (internal diameter 1.049 in, C = 120) the Hazen-Williams formula gives:</p>
<pre>p = 4.52 × Q^1.85 ÷ (C^1.85 × d^4.87) = 0.37 psi per ft
velocity ≈ 13 ft/s (4.0 m/s)</pre>
<p>That is fine over the short run at the end of a branch line. Add a third sprinkler to the same 1 inch pipe and the flow rises to 53 gpm: friction more than doubles to about 0.79 psi per ft and velocity reaches nearly 20 ft/s. That is why the third sprinkler moves the pipe up to 1¼ inch. Check any pipe this way with the <a href="https://tools.mepbase.com/fire-hydraulic-calculator">Fire Hydraulic Calculator</a>, and get sprinkler flow from pressure with the <a href="https://tools.mepbase.com/sprinkler-k-factor-calculator">Sprinkler K-Factor Calculator</a>.</p>
<h2 id="branch">Worked Example 1: Branch Line with 8 Sprinklers</h2>
<ol>
<li><strong>Start at the dead end.</strong> Number the sprinklers 1 to 8 from the far end of the branch line back towards the cross main.</li>
<li><strong>Count what each pipe carries.</strong> Each pipe segment carries every sprinkler beyond it, so the segment before sprinkler 3 carries 3.</li>
<li><strong>Read the size from the table.</strong> Use the column for your hazard class and pipe material.</li>
</ol>
<table>
<thead>
<tr>
<th>Pipe segment</th>
<th>Sprinklers downstream</th>
<th>Pipe size</th>
</tr>
</thead>
<tbody>
<tr>
<td><strong>End sprinkler to sprinkler 2</strong></td>
<td>1</td>
<td>1 in</td>
</tr>
<tr>
<td><strong>Sprinkler 2 to 3</strong></td>
<td>2</td>
<td>1 in</td>
</tr>
<tr>
<td><strong>Sprinkler 3 to 4</strong></td>
<td>3</td>
<td>1¼ in</td>
</tr>
<tr>
<td><strong>Sprinkler 4 to 5</strong></td>
<td>4</td>
<td>1½ in</td>
</tr>
<tr>
<td><strong>Sprinkler 5 to 6</strong></td>
<td>5</td>
<td>1½ in</td>
</tr>
<tr>
<td><strong>Sprinkler 6 to 7</strong></td>
<td>6</td>
<td>2 in</td>
</tr>
<tr>
<td><strong>Sprinkler 7 to 8</strong></td>
<td>7</td>
<td>2 in</td>
</tr>
<tr>
<td><strong>Sprinkler 8 to cross main</strong></td>
<td>8</td>
<td>2 in</td>
</tr>
</tbody>
</table>
<p>A full 8-sprinkler branch line therefore runs <strong>1&#8243; – 1&#8243; – 1¼&#8221; – 1½&#8221; – 1½&#8221; – 2&#8243; – 2&#8243; – 2&#8243;</strong>, the same in light and ordinary hazard. The pipe schedule limits a branch line to <strong>8 sprinklers on each side of the cross main</strong>, with only small exceptions in NFPA 13.</p>
<h2 id="crossmain">Worked Example 2: Cross Main with 48 Sprinklers</h2>
<p>Six branch lines of 8 sprinklers each are fed from one cross main. Count from the far end again:</p>
<table>
<thead>
<tr>
<th>Cross main segment</th>
<th>Sprinklers downstream</th>
<th>Light hazard</th>
<th>Ordinary hazard</th>
</tr>
</thead>
<tbody>
<tr>
<td><strong>After 1st branch line</strong></td>
<td>8</td>
<td>2 in</td>
<td>2 in</td>
</tr>
<tr>
<td><strong>After 2nd branch line</strong></td>
<td>16</td>
<td>2½ in</td>
<td>2½ in</td>
</tr>
<tr>
<td><strong>After 3rd branch line</strong></td>
<td>24</td>
<td>2½ in</td>
<td><strong>3 in</strong></td>
</tr>
<tr>
<td><strong>After 4th branch line</strong></td>
<td>32</td>
<td>3 in</td>
<td>3 in</td>
</tr>
<tr>
<td><strong>After 5th branch line</strong></td>
<td>40</td>
<td>3 in</td>
<td>3 in</td>
</tr>
<tr>
<td><strong>Feed main (all 6 lines)</strong></td>
<td>48</td>
<td>3 in</td>
<td><strong>3½ in (or 4 in)</strong></td>
</tr>
</tbody>
</table>
<p>The same 48 sprinklers need a 3 inch feed in an office but 3½ or 4 inch in a car park. This is exactly where using the wrong hazard table fails an inspection.</p>
<h2 id="coverage">Coverage Area per Sprinkler</h2>
<p>The pipe schedule assumes standard spray sprinklers at normal spacing, so it also limits the area each sprinkler may cover:</p>
<table>
<thead>
<tr>
<th>Hazard</th>
<th>Max area per sprinkler</th>
<th>Max spacing</th>
</tr>
</thead>
<tbody>
<tr>
<td><strong>Light hazard</strong></td>
<td>200 ft² (18.6 m²) with pipe schedule; 225 ft² (20.9 m²) if hydraulically calculated</td>
<td>15 ft (4.6 m)</td>
</tr>
<tr>
<td><strong>Ordinary hazard</strong></td>
<td>130 ft² (12.1 m²)</td>
<td>15 ft (4.6 m)</td>
</tr>
</tbody>
</table>
<p><em>Maximum distance to a wall is half the spacing, 7.5 ft (2.3 m).</em></p>
<p>Check a layout against these limits and the design density with the <a href="https://tools.mepbase.com/sprinkler-density-calculator">Sprinkler Density Calculator</a>.</p>
<h2 id="when">When Can You Use the Pipe Schedule Method?</h2>
<p>The pipe schedule is simple, but NFPA 13 now restricts it. Use it only when all of these apply:</p>
<ol>
<li><strong>Light or ordinary hazard only.</strong> Extra hazard and storage always need a hydraulic calculation.</li>
<li><strong>Small or existing systems.</strong> A new system of 5,000 ft² (465 m²) or less, or an addition or change to an existing pipe schedule system. Larger new systems qualify only where the supply gives the required flow at 50 psi residual or more at the highest sprinkler.</li>
<li><strong>Enough water supply.</strong> Including hose streams, roughly 500–750 gpm at 15 psi residual for light hazard and 850–1,500 gpm at 20 psi for ordinary hazard, for the required duration.</li>
<li><strong>The authority accepts it.</strong> Many civil defence authorities in the Gulf ask for hydraulic calculations on every new project, so check before you submit.</li>
</ol>
<p>For everything else, size the pipes by hydraulic calculation. The method is explained in the <a href="https://mepbase.com/fire-fighting-system-design-calculation/">fire fighting system design calculation</a> guide, with the full background in the <a href="https://mepbase.com/fire-fighting-system-complete-course/">fire fighting system complete course</a>.</p>
<h2 id="abovebelow">Sprinklers Above and Below a Ceiling</h2>
<p>Where the same branch lines feed sprinklers both above and below a ceiling, for example in a combustible ceiling void, NFPA 13 has a separate table that allows more sprinklers on the smaller pipe sizes, and a branch line may carry up to 8 sprinklers above and 8 below. Do not use the standard tables above for these lines; take the values from the NFPA 13 edition your authority has adopted.</p>
<h2 id="mistakes">Common Mistakes</h2>
<ol>
<li><strong>Light hazard numbers in ordinary hazard areas.</strong> A kitchen, car park or plant room inside an office building is ordinary hazard. From 2½ inch upwards its pipes follow the ordinary hazard table.</li>
<li><strong>Counting from the wrong end.</strong> Always count the sprinklers downstream of the pipe, starting from the dead end of the branch line.</li>
<li><strong>Mixing steel and copper columns.</strong> The higher copper numbers apply only to copper tube. CPVC follows its own listing.</li>
<li><strong>Forgetting the minimum size.</strong> Steel sprinkler pipe must be at least 1 inch. Copper tube may go down to ¾ inch, but only in hydraulically calculated systems.</li>
<li><strong>Using the table where it is not permitted.</strong> A large new building almost always needs a hydraulic design, even if the pipe sizes end up similar.</li>
</ol>
<p><strong>Size it properly in minutes:</strong> check flow, friction loss and pressure at every sprinkler instead of relying on the table alone with the <a href="https://tools.mepbase.com/fire-hydraulic-calculator">Fire Hydraulic Calculator →</a></p>
<div class="mb-faq">
<h2 id="faq">Frequently Asked Questions</h2>
<details open="">
<summary>What size pipe do I need for 2 sprinklers?</summary>
<div class="mb-faq-a">
<p>A 1 inch (DN25) pipe. Under the NFPA 13 pipe schedule a 1 inch steel or copper pipe can feed a maximum of 2 sprinklers in both light hazard and ordinary hazard.</p>
</div>
</details>
<details>
<summary>How many sprinklers can a 1 inch pipe supply?</summary>
<div class="mb-faq-a">
<p>Two. A third sprinkler needs 1¼ inch pipe, four or five need 1½ inch, and six to ten need 2 inch steel pipe.</p>
</div>
</details>
<details>
<summary>How many sprinklers can a 2 inch pipe supply?</summary>
<div class="mb-faq-a">
<p>Ten in steel pipe and twelve in copper tube, in both light and ordinary hazard.</p>
</div>
</details>
<details>
<summary>How many sprinklers on a 3 inch pipe?</summary>
<div class="mb-faq-a">
<p>In steel pipe, 60 in light hazard but only 40 in ordinary hazard. Copper allows 65 and 45.</p>
</div>
</details>
<details>
<summary>Is the pipe schedule method still allowed?</summary>
<div class="mb-faq-a">
<p>Yes, but only for light and ordinary hazard, mainly for new systems up to 5,000 ft² and for changes to existing pipe schedule systems. Most new projects are designed by hydraulic calculation, and many authorities require it.</p>
</div>
</details>
<details>
<summary>How many sprinklers can be on one branch line?</summary>
<div class="mb-faq-a">
<p>Eight on each side of the cross main under the pipe schedule method, with only limited exceptions in NFPA 13. Hydraulically calculated systems have no fixed count but must meet pressure and flow at every sprinkler.</p>
</div>
</details>
</div>
<h2>Free Resources</h2>
<ul>
<li><a href="https://mepbase.com/fire-sprinkler-distribution-autolisp-free-download/">Fire sprinkler distribution AutoLISP</a></li>
<li><a href="https://mepbase.com/fire-fighting-threaded-fittings-cad-blocks/">Fire fighting threaded fittings CAD blocks</a></li>
<li><a href="https://mepbase.com/black-steel-pipe-dynamic-block-dwg/">Black steel pipe dynamic block</a></li>
<li><a href="https://mepbase.com/basement-fire-fighting-shop-drawing-free-download/">Basement fire fighting shop drawing</a></li>
<li><a href="https://tools.mepbase.com/pipe-schedule-reference">Pipe Schedule Reference (dimensions and wall thickness)</a></li>
</ul>
<h2>References</h2>
<ul>
<li>NFPA 13, Standard for the Installation of Sprinkler Systems: pipe schedule method, light hazard and ordinary hazard pipe schedules</li>
<li>NFPA 13: water supply requirements for pipe schedule systems</li>
<li>Hazen-Williams friction loss formula as used in NFPA 13 hydraulic calculations</li>
</ul>
<p><em><strong>Written by Faisal</strong>, MEP engineer with 16+ years in fire protection design and shop drawings. Pipe schedule values are from NFPA 13; always check the edition adopted by your local authority and its requirements.</em></p>